EXAFAN products, always at the avant–garde within our sector.

Accessories for chimney fans

Complete chimney for corrugated appentice roof

Associated documents

Complete chimney for corrugated appentice roof

Radial or centrifugal fans that propel air in a radial way. The air inlet forms a 90º angle with the outlet in such a way that the air enters axially and is expelled outside radially.

MODELS

Ref Subst Description
CH35 18010 Complete chimney Ø 35. for corrugated appentice roof
CH40 18020 Complete chimney Ø 40. for corrugated appentice roof
CH45 18030 Complete chimney Ø 45. for corrugated appentice roof
CH50 18040 Complete chimney Ø 50. for corrugated appentice roof
CH56 18050 Complete chimney Ø 56. for corrugated appentice roof

TECHNICAL DATA

STACKABLE A B C D E F G H I J K L
CH-35 35 44,5 195 134 3,5 44,5 43,3 2,2 11,5      
CH-40 40 50 195 134 3,5 50 40,2 2,2 11,5      
CH-45 45 55 195 134 3,5 55 44,7 2,2 11,5      
CH-50 50 59,5 195 134 3,5 59,5 48,9 2,2 11,5      
CH-56 56   195 134 3,5 64,5 55,6 2,2 11,5      
Roof canopy                   48 140 50

 

MODELS OF COWLS M N
S-75 75 11
S-95 95 11

*Approximate measures in cm

Complete chimney for flat appentice roof

Associated documents

Complete chimney for flat appentice roof

Radial or centrifugal fans that propel air in a radial way. The air inlet forms a 90º angle with the outlet in such a way that the air enters axially and is expelled outside radially.

MODELS

Ref Subst Description
CH35-PLANO 18400 Complete chimney Ø 35. for flat appentice roof
CH40-PLANO 18410 Complete chimney Ø 40. for flat appentice roof
CH45-PLANO 18420 Complete chimney Ø 45. for flat appentice roof
CH50-PLANO 18430 Complete chimney Ø 50. for flat appentice roof
CH56-PLANO 18400 Complete chimney Ø 56. for flat appentice roof

TECHNICAL DATA

STACKABLE A B C D E F G H I J K L
CH-35 35 44,5 195 134 3,5 44,5 43,3 2,2 11,5      
CH-40 40 50 195 134 3,5 50 40,2 2,2 11,5      
CH-45 45 55 195 134 3,5 55 44,7 2,2 11,5      
CH-50 50 59,5 195 134 3,5 59,5 48,9 2,2 11,5      
CH-56 56   195 134 3,5 64,5 55,6 2,2 11,5      
Roof canopy                   48 140 50

 

MODELS OF COWLS M N
S-75 75 11
S-95 95 11

 

*Approximate measures in cm

Pile up chimney for corrugated appentice roof

Associated documents

Pile up chimney for corrugated appentice roof

Exafan has created a new type of removable and stackable chimney designed to work in air extraction mode, to lead the air flow inside the farm towards the required areas thanks to its diffusor. 

The concepts of conic entrance with a conic exit are both linked, this way; we manage to link the notion of easy assembly and transportation optimization with that of efficiency and ventilation system performance in one single product.

MODELS  

Ref Subst Description
CH56-APILAB-NEG 19200 Pile up chimney Ø 56 for corrugated appentice roof
CH63-APILAB-NEG 19210 Pile up chimney Ø 63 for corrugated appentice roof
CH71-APILAB-NEG 19220 Pile up chimney Ø 71 for corrugated appentice roof
CH80-APILAB-NEG 19230 Pile up chimney Ø 80 for corrugated appentice roof

TECHNICAL DATA

STACKABLE A B C D E F G H I J K L M
CH-56 89,2 70 52 184 7,5 55 69 2,2          
CH-63 83,5 68 49,5 178 7,5 62,5 70 2,2          
CH-71 100 70 50,5 187 7,5 68,5 81 2,2          
Cowl S-130                       131 20
Conic cowl                       71 145
Roof canopy                   49 140 52  

 

* Approximate measures in cm

* Our stackable conic chimneys always use the cowl S-130

  • 1. Cowl with legs. 
  • 2. Butterfly valve. 
  • 3. Upper conic part. 
  • 4. Stackable extension lot. 
  • 5. Motor. 
  • 6. Lower conic part. 
  • 7. Cone to diffuse the air flow. 

The marks engraved on the chimney body ensure an easy and exact position of the fan.

Aerodynamics : The air guide or the air inlet cone of the ventilation chimney was designed to favor the air flow and improve the global aerodynamic performance of the ventilation chimney.

Air flow: The ventilation chimney was designed to provide with the maximum air flow by reducing the fan electric consumption due to the conic shape of the air outlet enlargement producing a Venturi effect. They offer the possibility of a more simple and reduced room, which makes them more practical and economic. 7 times greater transportation capacity than for conventional chimneys.

The new conic chimney model allows a more fluid and quicker air extraction due to the Venturi effect caused by the air inlet and outlet through the chimney. 

The conic inlet and outlet construction principle ensures an improvement of the fan performance.

STACKABLE complete chimney with a flat roof canopy

Associated documents

STACKABLE complete chimney with a flat roof canopy

Exafan has created a new type of removable and stackable chimney designed to work in air extraction mode, to lead the air flow inside the farm towards the required areas thanks to its diffusor. 

The concepts of conic entrance with a conic exit are both linked, this way; we manage to link the notion of easy assembly and transportation optimization with that of efficiency and ventilation system performance in one single product.

MODELS  

Ref Susbt Description
CH56-APILAB-NEG-PLAN 19201 Pile up chimney Ø 56 for flat appentice roof
CH63-APILAB-NEG-PLAN 19211 Pile up chimney Ø 63 for flat appentice roof
CH71-APILAB-NEG-PLAN 19221 Pile up chimney Ø 71 for flat appentice roof
CH80-APILAB-NEG-PLAN 19231 Pile up chimney Ø 80 for flat appentice roof

TECHNICAL DATA

STACKABLE A B C D E F G H I J K L M
CH-56 89,2 70 52 184 7,5 55 69 2,2          
CH-63 83,5 68 49,5 178 7,5 62,5 70 2,2          
CH-71 100 70 50,5 187 7,5 68,5 81 2,2          
Cowl S-130                       131 20
Conic cowl                       71 145
Roof canopy                   49 140 52  

 

Approximate measures in cm

Our stackable conic chimneys always use the cowl S-130

  • 1. Cowl with legs. 
  • 2. Butterfly valve. 
  • 3. Upper conic part. 
  • 4. Stackable extension lot. 
  • 5. Motor. 
  • 6. Lower conic part. 
  • 7. Cone to diffuse the air flow. 

 

The marks engraved on the chimney body ensure an easy and exact position of the fan.

Aerodynamics : The air guide or the air inlet cone of the ventilation chimney was designed to favor the air flow and improve the global aerodynamic performance of the ventilation chimney.

Air flow: The ventilation chimney was designed to provide with the maximum air flow by reducing the fan electric consumption due to the conic shape of the air outlet enlargement producing a Venturi effect. They offer the possibility of a more simple and reduced room, which makes them more practical and economic. 7 times greater transportation capacity than for conventional chimneys.es.

The new conic chimney model allows a more fluid and quicker air extraction due to the Venturi effect caused by the air inlet and outlet through the chimney. 

The conic inlet and outlet construction principle ensures an improvement of the fan performance.

Universal tube

Associated documents

Universal tube

MODELS 

Ref Subst Description
TUBO-35+CONO-NEGRO 18060 Tube 2 m + cone Ø 35
TUBO-40+CONO-NEGRO 18070 Tube 2 m + cone Ø 40
TUBO-45+CONO-NEGRO 18080 Tube 2 m + cone Ø 45
TUBO-50+CONO-NEGRO 18090 Tube 2 m + cone Ø 50
TUBO-56+CONO-NEGRO 18100 Tube 2 m + cone Ø 56

Pile up pipe of stackable chimney

Associated documents

Pile up pipe of stackable chimney

MODELS

Ref Subst Description
TUBO-56-APILAB-NEGRO 18450 Pile up pipe of 1,70 m and Ø 56 + cone
TUBO-63-APILAB-NEGRO 18460 Pile up pipe of 1,70 m and Ø 63 + cone
TUBO-71-APILAB-NEGRO 18470 Pile up pipe of 1,70 m and Ø 71 + cone
TUBO-80-APILAB-NEGRO 18480 Pile up pipe of 1,70 m and Ø 80 + cone

Universal appentice roof for chimney

Associated documents

Universal appentice roof for chimney

Universal roof designed for any slope to be found in farms and for whatever EXAFAN chimney size.

MODELS

Ref Subst Description
TEJADILLO-NEGRO 18110 Universal appentice roof for chimney Ø 35 till Ø 71
EJADILLO-PLANO-NEGRO 18111 Flat universal appentice roof Ø 35 till Ø 71

 

TECHNICAL DATA

J K I
35,5 110x116 37

 

Extension for chimney

Associated documents

Extension for chimney

MODELS

Ref Subst Description
EXT35 18180 Extension for chimney Ø 35
EXT40 18190 Extension for chimney Ø 40
EXT45 18200 Extension for chimney Ø 45
EXT50 18210 Extension for chimney Ø 50
EXT56 18220 Extension for chimney Ø 56

Extension for pile up chimney

Associated documents

Extension for pile up chimney

MODELS

Ref Subst Descripction
EXTENSION-56-CONJ-NE 18227 Extension for chimney Ø 56 Pile Up
EXTENSION-63-CONJ-NE 18226 Extension for chimney Ø 63 Pile Up

Butterfly valve

Associated documents

They work to hinder the intake of the air flow the opposite way, also to hinder the entrance of atmospheric phenomena as water or snow when the fan has stopped.

MODELS

Ref Subst Description
VAL-MARIPOSA-35-NX1825 18250 Butterfly valve Ø 35
VAL-MARIPOSA-40-NX 18251 Butterfly valve Ø 40
VAL-MARIPOSA-45-NX 18252 Butterfly valve Ø 45
VAL-MARIPOSA-50-NX 18260 Butterfly valve Ø 50
VAL-MARIPOSA-56-NX 18261 Butterfly valve Ø 56

Pile Up Butterfly valve

Associated documents

Pile Up Butterfly valve 

Conçues pour empêcher l´entrée des courants d´air dans le sens inverse, ainsi que des phénomènes atmosphériques comme par exemple l´eau ou la neige, lorsque le ventilateur a arrêté.

MODELS

Ref Subst Description
VAL-MARIP-56-AP-NX-C 18263 Pile Up Butterfly valve Ø 56 
VAL-MARIP-63-AP-NX-C 18264 Pile Up Butterfly valve Ø 63 
VAL-MARIP-71-AP-NX-C 18265 Pile Up Butterfly valve Ø 71 

Standard chimney Hat

Associated documents

Hat for standard chimney 

The installation of the cover on the chimney prevents the ainlet of non-wished atmospherical phenomenons in our facilities.

MODELS

Ref Subst Description
SOMBRERETE-75-NEGRO 18230 Hat Ø 75: (Ø 35, Ø 40, Ø 45, Ø 50)
SOMBRERETE-95-NEGRO 18240 Hat Ø 95 (Ø 56)
SOMBRERETE-95 -OSCUR 18242 Hut Ø 95 cm. Light trap

Polyester hat for piled chimneys

Associated documents

Polyester hat for piled chimneys

The installation of the cover on the chimney prevents the ainlet of non-wished atmospherical phenomenons in our facilities.

MODELS

Ref Subst Description
SOMBRERETE-130-NEGRO 18243 Polyester hat of Ø130 cm for piled chimneys. valid for models (Ø 56, 63, 71 et 80)
SOMBRERETE-130-OSCUR 18244 Darken hat of Ø130cm for piled chimneys.valid for models  Ø 56, 63, 71, 80

Flow regulation valve

Associated documents

Flow regulation valve

The diaphragm hatch, wich is manually handled, reduces the size of chimney air inlet.

MODELS

Ref Subst Description
VRC-35 18300 Flow regulation valve of: Ø 35
VRC-35-M-EST 18311 Flow regulation valve Ø 35 for watertight motor
VRC-40 18320 Flow regulation valve of Ø 40
VRC-40-M-EST 18331 Flow regulation valve Ø 40 for watertight motor
VRC-45 18340 Flow regulation valve of Ø 45
VRC-45-M-EST 18351 Flow regulation valve Ø 45 for watertight motor
VRC-50 18360 Flow regulation valve of Ø 50
VRC-50-M-EST 18371 Flow regulation valve Ø 50 for watertight motor
VRC-56 18380 Flow regulation valve of Ø 56
VRC-56-M-EST 18391 Flow regulation valve Ø 56 for watertight motor
VRC-63 18395 Flow regulation valve of Ø 63
VRC-63-M-EST 18397 Flow regulation valve Ø 63 for watertight motor

Pile Up Flow regulation valve

Associated documents

Pile Up Flow regulation valve 

The diaphragm hatch, wich is manually handled, reduces the size of chimney air inlet

MODELS

Ref Subst Description
VRC-56-APILABLE 18600 Pile Up Flow regulation valve Ø 56 
VRC-56-MOTOR-EST-API 18602 Pile Up Flow regulation valve of Ø 56 for watertight motor
VRC-63-APILABLE 18610 Pile Up Flow regulation valve Ø 63
VRC-63-MOTOR-EST-APIT 18612 Pile Up Flow regulation valve of Ø 63 for watertight motor
VRC-71-APILABLE 18620 Pile Up Flow regulation valve Ø 71 
VRC-71-MOTOR-EST-API 18622 Pile Up Flow regulation valve of Ø 71 for watertight motor