Air inlet control system

RCI
Associated documents
The RCI main gial is to save energy; it has a very efficient program that thanks to the weather station comes up to work with the air inlet / curtain in an optimal way since fans only operate whenever is required by the climate conditions.
CHART OF FEATURES
INLETS | Inside temperature | 2+2 | |
Outside temperature | 1 | ||
Relative humidity | 1 | ||
Weather station | 1 | ||
MV1 powermeter | 2 | ||
OUTPUT | Analogical | For fans | 3 |
For air inlets | 2 | ||
For inlets | 1 | ||
Digital | Heating | 1 | |
Cooling | 1 | ||
Alarm | 1 | ||
Motor control | Bandwidth control | 2 | |
VARIUS | Bandwidth control | ||
Control of minimums / maximums | |||
Work with influences | |||
Work with influences static/ cross sectional / tunnel way of working | |||
PC loop communication |
Ref | Subst | Motor | Climate controller | Shape | |||
Weight with hoist winch | Motor outlet | End of stoke | Power | Power | |||
RCI1T-T | 09150 | 1000 Kg | Coil | Yes | Three phase | 230 V a.c | 1 Winch |
RCI2T-T | 09070 | 1000 Kg | Coil | Yes | Three phase | 230 V a.c | 2 Winches |
RCI1T-M | 09150-M | 1000 Kg | Coil | Yes | Single phase | 230 V a.c | 1 Winch |
RCI2T-M | 09070-M | 1000 Kg | Coil | Yes | Single phase | 230 V a.c | 2 Winches |
RCI-T
CROSS SECTION RCI
Static or natural: The RC works in a static ventilation way and taking advantage of the wind strength whenever the (direction and speed) are convenient, fans will be kept turned off with the corresponding energy saving.
Dynamic or forced: Fans will work in a forced way whenever the desired parameters are not stored while working in an energy saving basis, therefore the air inlets placed on the side of the mentioned fans will be closed, these side fans will turn on and increase their speed according to the required air flow.
RCI-C
Static or natural: The RCI works in a static ventilation format while taking advantage of the wind strength, therefore fans shall be kept turned off and will save energy whenever the conditions (direction and speed) are convenient.
Dynamic or forced: The climate controller will operate in a forced ventilation format whenever the desired parameters are not stored while working in an energy saving basis, therefore side air inlets will position themselves and chimney fans will the run.
TUNNEL RCI-T
Static or natural: The RCI works with the air inlets while using wind strength, as long as the conditions (direction and speed) are convenient, fans will be kept turned off and therefore saving energy.
Dinámica tunnel: All the side air inlets are closed and by means of the peripheral (EGC) all the exhaust fan ventilation phases placed in front of the farm start working and achive optimal environmental cooling thanks to the air flow produced.
NATURAL RCI
This version monitors both sides of the air inlets independently while combining the lintel supervision since it has a specific parameter control for it. It is the ideal system to control farms without fans.
RCI TUNNEL WITH CENTRAL UNIT
Static or natural: The RCI works in a static ventilation way taking advantage of the wind strength while conditions are convenient. These fans will be kept turned off with corresponding energy saving.
Dynamic or forced: In terms of minimum ventilation, air inlets perform ar a 50% and work with the fans placed in the upper part. In terms of maximum fans, all the air inlets are closed; chimney as well as those placed in front of the farm are activated and therefore tunnel ventilation is now on its way.
RCI TUNNEL WITH CROSS SECTION
Static or natural: The RCI works in a static ventilation way taking advantage of the wind strength while conditions are convenient. These fans will be kept turned off with the corresponding energy saving.
Dynamic or forced: All the air inlets close and stop working, then side fans shall start working little by little while the exhaust ones placed in front of the farm turn on.
TUNNEL WITH CENITAL UNITL / TUNNEL WITH CROSS SECTION
MIXED CROSS SECTION
Static or natural: The RCI works in a static ventilation way taking advantage of the strength while conditions are convenient. These fans will be kept turnedd off with the corresponding energy saving.
Dynamic or forced: Te curtains placed beside the fans close themselves and the small fans start working, afterwards, exhaust fans will do the same whenever ventilation requirements.
RAV1T-T
Associated documents
Automatic air inlet control system with:
•RAV Regulator •230 V CA supply regulator.•With probe included.
• 1 Reduction motor for 1.000 Kg (With hoist) • Motor output reel type• Line end incorporated • Reduction motor three phasic 230/430 V